Feeder Troubleshooting

S.NoCodeFaultCauseCorrective Action
1FG-01 Feeder will not startPower failure.Check power supply.
   Starter inoperative.Check fuses, breakers, holding coil, heater.
   Motor does not operate.Refer to FG-02
2FG-02Motor doesn't operateInsufficient line voltageCheck electrical supply for sufficient line voltage.
   Fuse or circuit breaker blown.Replace or reset, Fuse or circuit breaker.
    Cams jammed with outer cover."Remove the cover and run the motor.

Replace the outer cover with suitable clearance.

Do not run without cover."
   Defective power cable.Check cable for broken conductors replace if defective
3FG-03Fatigue failure of Feeder body. Field modifications by user, welding, cutting, etc., which concentrate abnormal stresses."Include design requirements in initial specification.

Replace failed components"
   Corrosion and wear.Replace damaged parts.
   Feeder operating out of balance.Restore balance.
   Operating Feeder at or near critical speed."Change speed, Consult Manufacturer.

Refer FG-07."
   Excessive feed rate.Reduce feed.
   Oversize feed materials. Reduce maximum size of feed.
   Interference with structure or material build-up.Eliminate interference of build-up.
4FG-04Motor OverheatsMotor wired incorrectly. Correct wiring-consult Mfr. for proper size.
   Motor too small.Consult Mfr.
   Defective motorReplace or rewind defective motor.
   Power circuit wire too small.Install power circuit with correct wire size
   Power circuit overloaded.Install heavier circuit or reduce load on power circuit.
5FG-05Excessive Feeder VibrationDamaged suspension. Replace damaged parts.
   High unbalance forces.Adjust the CAM of motor to reduce the unbalance.
   Wrong stroke/speed combination."Ensure the motor cables are as per wiring instruction.
Consult Manufacturur."
   Improper or surge feeding. Control feed of material.
6FG-06Excessive Structure VibrationSupport structure too weak. Add structural support.
   Insufficient clearance between Feeder and neighbouring structure.Provide adequate clearance and/or remove interfering component/structure.
   Fatigued suspension parts.Replace components and check other components for damage.
7FG-07Erratic VibrationVoltage drop.Check power supply.
   Broken suspension parts.Replace suspension parts tighten.
   Loose body bolts.Replace or properly bolts as per standard torque rating.
   Feeder operating at or near critical speed.Change speed as per manufacturer's recommendations.
   Motor Cam settings changed and do not match factory setting.Contact company for correct setting.
8FG-08Noisy FeederSupport structure too weak. Add structural support.
   Broken suspension parts.Replace suspension parts tighten as per standard torque rating.
   Loose body bolts.Replace or properly bolts.
   Damaged suspension. Replace damaged parts.
   Wrong stroke/speed combination"Ensure the motor cables are as per wiring instruction.
Consult Manufacturur."